System information
Chapter 10 ‒ Networking
• 10/100 Mbps network speed
• RJ45 Ethernet ports
• Compatible with networked UHF-R receivers
• Automatic (DHCP enabled) IP addressing
• Class 1 Power over Ethernet (PoE) ports, as labeled
Networking Best Practices
Connecting components using an Ethernet network enables advanced Axient features such as automatic frequency
assignment, remote control and monitoring, and interference avoidance. Adding a computer to the network allows you to
run Wireless Workbench
®
6 (WWB6) to control and monitor devices on the network.
Axient components feature the following network specifications:
Use the following best practices when setting up a network to ensure reliable communication:
• Always use a "star" network topology
• Use only 1 DHCP enabled server per network. Disable DHCP addressing on additional servers
• When using an AXT620 Ethernet Switch, turn on the switch first before turning on additional components connected
to the network
• To expand the network, use multiple Ethernet switches in a star topology
• Connect each device directly to the port of an Ethernet switch. Avoid "daisy-chaining" Ethernet port connections
between devices for larger networks.
• Do not loop network connections
• All networked devices must be set to the same subnet mask
• All devices must be at the same firmware revision level, with the exception of the AXT620 Ethernet Switch
54