System information
Charging Batteries with the AXT900 Charger
Inserting Batteries into the Charging Bay
Slide the battery into the charging bay until it locks into place. The charge LED illuminates and the charge cycle begins.
• To remove handheld batteries: press the release button on the front of the charger module
• To remove bodypack batteries: press the release tabs on the sides and pull back
CALC calculating time to full
COLD Battery temperature = 0°C (32°F) or lower.
WARM Battery temperature = 45°C to 60°C (113°F to 140°F).
HOT Battery temperature = 60°C (140°F) or higher.
Recovery recovery mode active
Error error - press SET key for info
▲
▲
SET
4
3
2
1
8
7
6
5
Charge Status LED
Each charger bay has an LED to indicate the status of the battery.
Red battery charging
Green charging complete
Off battery inserted incorrectly, battery depleted below 3.0 volts, battery cold (< 0° C), battery hot (> 60° C)
Amber charging stopped at reduced capacity (not less than 75% capacity) because a battery is too warm. To
reach 100% capacity, a battery must be cooled to below 45°C
Home Screen
When powered on, the charger displays the home screen. Icons indicate the charge level of each battery, and the display
alternates to show approximate hours and minutes remaining until the battery is fully charged.
The numbers on the screen correspond to the charging bays 1 through 8 from left to right.
The following messages may be displayed next to the bay number to indicate battery status:
Troubleshooting
Charge status
LED does not
illuminate.
Battery is inserted incorrectly or battery cannot accept a charge. Check battery temperature.
Battery does not
charge
Battery discharged below 3.0 volts. Try another battery.
63
Chapter 11 ‒ Axient Rechargeable Battery System