System information
AXT900 Storage Mode
Use Storage mode to charge or discharge the batteries to
a level of 3.8 volts, which is ideal for long-term storage.
To enter Storage mode:
1. Enter the AXT900 utility menu by holding both arrow
keys.
2. Navigate to the Storage menu and press the SET key.
3. Use the arrow keys to select On.
The charge status LEDs indicate the voltage state:
• Red flashing = battery charging or discharging to 3.8
volts.
• Amber flashing = battery voltage at 3.8 volts.
4. Press both arrow keys to return to the Monitoring
Menu.
The following indicators appear on the home screen next
to each bay number:
Rdy battery at 3.8 V, ready for storage
Cold battery cold
Wrm battery warm
Hot battery hot
Err Error, press SET key for info
% percentage of charge
Charging or discharging may take several hours.
The remaining time is displayed as Time to 3.8 V in
the battery monitoring menu (instead of Time to Full).
To exit storage mode:
1. Enter the utility menu by holding both arrow keys.
2. Navigate to the Storage Mode menu and press the SET key.
3. Use the arrow keys to select Off.
4. Press the SET key to exit.
Recovering a Battery from Deep Discharge
A deeply discharged battery is one that has been discharged to less than 3.0 volts. When the charger detects a deeply
discharged battery, it automatically enters recovery mode, which charges the battery using a reduced current. The
Recovery icon is displayed next to the bay number on the home screen. If recovery is successful, the charger exits
recovery mode and charges the battery to capacity.
If the battery cannot be recovered within 30 minutes, an error message is displayed and charging stops. Remove the
battery from service and check with local vendor for proper disposal of used batteries.
When batteries are ready for storage, they should be removed from the charger and placed into a temperature controlled area. Recommended battery
storage temperature is 0°C (10°F) to 25°C (77°F).
65