System information

Charging Batteries with a Portable Charging Station
Connecting DC Power
1. Connect the cable from the Shure PS50 power supply
to the DC power supply input.
2. The white LED will illuminate when the PS50 is
connected to an AC power source.
Inserting and Removing Handheld Batteries
To Insert:
1. Slide the battery into the charging bay.
2. Press the battery until it locks into place.
To Remove:
1. Press the release button on the front of the charger
module.
2. The release mechanism will eject the battery from the
charger module.
Charge Status LED
Each charger bay has an LED to indicate the status of the battery.
Red battery charging
Green charging complete
Off battery inserted incorrectly, battery depleted below 3.0 volts, battery cold (< 0° C), battery hot (> 60° C)
Amber charging stopped at reduced capacity (not less than 75% capacity) because the battery is too warm. To
reach 100% capacity, the battery must be cooled below 45°C
Inserting and Removing Bodypack Batteries
To Insert:
1. Align the battery with the charger bay.
2. Press the battery into the charging bay until it locks into
place.
To Remove:
Press the release tabs on the sides of the battery and pull
back.
Troubleshooting
Power LED off. DC power fault - check connection to power supply. Ensure PS50 power supply is connected to an
AC power source.
Charge status
LED does not
illuminate.
Battery is not fully inserted.
Battery does not
charge
Battery discharged below 3.0 volts. Try another battery.
The AXT903 and AXT904 Portable Charging Stations charge 2 transmitter batteries in a convenient and compact desktop
unit. Use the AXT903 to charge bodypack transmitter batteries or the AXT904 to charge handheld transmitter batteries.
66