One Active Mic per Channel
Only one microphone will operate on the channel at a time, blocking the second microphone from interfering with the RF and
audio performance. The backup microphone briefly flashes the LED to indicate the channel is occupied, and automatically
turns off to conserve the battery. To use the second microphone, simply turn off the first microphone.
Two Microphones Ready for the Audio Channel
The system allows one live microphone per channel.
Procedure
Link a single microphone:
Place the secondary microphone into the same charging slot that was used for the primary microphone.
Open the MXW control software and go to the Monitor tab.
Select Secondary in that channel's link slot.
Select the Link button on the channel strip to link that microphone. The charger LEDs will flash when the procedure is
complete.
Link multiple microphones:
Place the secondary microphones into the same charging slots that were used for the primary microphones.
Open the MXW control software and go to the Configuration tab.
Find the desired charger in the group row. Use the ID button to make sure the right charger is selected.
Select the Link button in the group row.
In the popup window, select All Secondary for the link slot.
Exchanging or Removing a Component
Exchanging a Transmitter
The same Link procedure is done to exchange a transmitter in a group. Place the new transmitter in the charger slot that corre
sponds to the desired channel and perform the Link procedure. This will map the new transmitter to that channel, and remove
any Link from the old transmitter.
If an NCS channel slot is empty during the Link procedure, the channel will remain unaffected.
Important: Use caution when replacing microphones, as the Link procedure applies for all microphones in the charger. The Link will immediately override any