1.
Density Mode Comparison
Feature Standard Density High Density
Channels available* Up to 40 Up to 80
Audio latency 18 ms 28 ms
Microphone battery life Up to 7 hours Up to 8 hours
EQ filters Optional Always on
Backchannel audio (headphone out
put on the microphone)
Available Unavailable
*For Americas region. See Maximum Channel Count table for availability worldwide.
Setting the Density Mode
Set the mode for each APT from the device properties:
Go to MXW
control
software > Utility
tab > [Find
the
desired
APT] > Edit
Choose a density mode:
Standard (default)
High
Select Add updates to exit the device properties.
Select Apply All from the Utility page to push to your devices.
Configurations: Managing Multiple Groups
Configurations allow multiple Groups to share the same preferences, global controls and log-ons. When an additional Group is
added to the Configuration tab, the new components will take on the preferences and global actions of that Configuration. For
example, all microphones Linked to Groups in that Configuration will mute when the global Mute All button is pressed.
For specialized applications, such as multiple room installation, separate Configurations can be created to independently con
trol component Groups.
Configuration Master
When using a Configuration to manage multiple groups, the system dynamically assigns a particular Access Point as the “Con
figuration Master". All Access Points in that Configuration use the Configuration Master Access Point as an entry point to the
same control interface. This enables the coordination of preferences and the synchronization of system operations across mul
tiple devices.
When the Configuration Master Access Point is unplugged (or PoE is powered off), a new master is quickly re-established to
maintain control of the Configuration. If the Configuration Master is manually removed by deselecting the Access Point from the
Group on the Configuration tab, there will be a pop-up warning "Are You Sure?". If Yes is selected, the browser will close and a
new Configuration Master is automatically selected. Use the Shure Discovery Application to re-open the control interface from
any remaining MXW Access Point.
Creating Separate Configurations
For installations that spread across multiple rooms, a different set of preferences and global controls may be required for a giv
en space. Do this by setting up a separate Configuration: