Installation and Operation Manual

911-396 Rev. J 12/01 Page: 1 of 4
2088 INDUSTRIAL SERIES PUMPS
Installation and Operation Manual
SHURflo offers various pumps models for different applications. The information outlined by this manual is
general, and not specific to all 2088 series pumps. Be certain the pumps' materials will be compatible with the
fluid being pumped. 2088 series pumps are intended for intermittent or continuous duty when the proper operating
criteria is met. Product Data Sheets outlining specific thermal limits, load, flow curves, and other technical
information for a particular model are available. If unsure of the chemical compatibility with a given elastomer or
the motors intended design, please call SHURflo for assistance.
CAUTION: "Intermittent Duty" is defined as; operated and/or frequently started within a period of time that
would cause the motor to reach its maximum thermal limits. Once the maximum thermal limit is
obtained, the motor must be allowed to return to ambient temperature before resuming operation.
CAUTION: DO NOT use to pump flammable liquids. Never operate the pump in an explosive environment.
Arcing from the motor brushes, switch or excessive heat from an improperly cycled motor may cause
an explosion.
CAUTION: DO NOT assume fluid compatibility. If the fluid is improperly matched to the pumps' elastomers, a
leak may occur. Pumps used to transfer hazardous or hot (max. temperature 170°F [76°C] viton
only) chemicals must be in a vented area to guard against the possibility of injury due to harmful or
explosive liquid/vapors.
CAUTION: DO NOT operate the pump at pressures which cause the motor to exceed the amperes rating
indicated on the name plate. Various pump models are equipped with thermal breakers to interrupt
operation due to excessive heat. Once the temperature of the motor is within proper limits it will
automatically reset, and the pump will start operation without warning.
CAUTION: To prevent electrical shock, disconnect power before initiating any work. In the case of pump
failure, the motor housing and/or the pumped fluid may carry high voltage to components normally
considered safe.
PRESSURE SWITCH OPERATION
The pressure switch reacts to outlet pressure, and interrupts power at the preset shut-off pressure indicated on the
pump label. When outlet pressure drops below a predetermined limit (typically 15-20 psi.[
1-1.4 bar
] less than the
shut-off pressure), the switch will close and the pump wil operate until the shut-off (high) pressure is achieved.
The shut-off pressure is set to factory calibrated standards. See the motor label and Product Data Sheet for specific
pump specifications.
CAUTION: Improper adjustment of the pressure switch, may cause severe overload or premature failure. Refer
to SHURflo Service Bulletin
#
1031 for the adjustment procedure. Failures due to improper
adjustment of the pressure switch will not be covered under the limited warranty.
If the plumbing is restrictive or the flow rate is very low, the pump may re-pressurize the outlet faster than the fluid
is being released causing rapid cycling (
ON/OFF within 2 seconds). If the pump is subjected to rapid cycling
during normal operation, or for infrequent periods, damage may occur. Applications which exhibit rapid cycling
should have restrictions in the outlet minimized. If not feasible considered a SHURflo Accumalator or a SHURflo
"bypass" model pump.
BYPASS OPERATION
A bypass pump may be used for applications that normally induce frequent start/stop of the motor, and thereby create a
potential for overheating. Models equipped with an internal bypass are designed to pump at high pressure while at low
flow rates. Bypass models equipped with a switch may operate for several seconds even though the outlet side has been
closed off. Contact SHURflo for information regarding bypass pumps.
MOUNTING

Summary of content (4 pages)