User Manual

Next Generation
Signal Enhancement
10. APC (DL)
The APC action in the DL path is
indicated.
11. APC (UL)
The APC action in the UL path is
indicated.
12. System Temperature
Prevailing system temperature is
indicated.
13. Power supply
Values of derived voltages are
displayed,
14. Converters ON/OFF
It indicates the relevant
information about equipped
converters.
IV) ALARMS (Figure 5)
Details of alarms displayed are given below:
S.NO. Alarm Indication Remarks
1. PA OFF (Manual)
Indicates the PA OFF (Manual)
condition in the DL &/or UL paths.
2. PA OFF (Auto)
Indicates the PA OFF (Auto) condition
in the DL &/or UL paths.
3. PA Power Low DL
When PA Power in DL path goes
below the set limit, is indicated
through the red LED.
4. PA Power High DL
When PA Power in DL path exceeds
the upper limit, is indicated through
the red LED.
5. DL PA Temperature High
When PA Temperature in DL path
exceeds limit.
6. UL PA Temperature High
When PA Temperature in UL path
exceeds limit.
7. LNA Alarm
Indicates the failure of LNA in DL/UL
paths.
8. VSWR Alarm
Indicates the mismatch condition at
the DL/UL RF ports resulting in
exceeding the VSWR limits.
9. Synthesizer fail for the
sub bands equipped.
Indicates the failure of relevant
synthesizer in DL/UL directions.
10. RSSI low (DL)
Indicates the exceeding lower limit of
RSSI in the DL direction.
11. RSSI high (DL)
Indicates the exceeding upper limit of
RSSI in the DL direction.
12. AC fail
Indicates the failure of AC mains to
the system.
13. DC fail
Indicates the failure of DC derived
voltages in the system.
14. System Temperature
Indicates the rise in temperature of
the system.
15. Door Open
Indicates the opening of the door of
the repeater.
Monitoring interval is 3 seconds i.e. after every 3 seconds data on the
monitoring window is refreshed.
All Rights Reserved Shyam Telecom Limited Page
14/32