Instruction manual

CVS-128
Chapter 5 Installation
0093112802-00 5-1
Chapter 5 Installation
5.1 Item of Caution on Installation
To exercise fully the performance of echo sounder, the installation of CVS-128 must be performed by
an engineer who is officially authorized by our company. The installation work includes the following
content.
(1) Unpacking the configuration items
(2) Inspection of configuration unit, spare, accessories and material for installation
(3) Check of power voltage and capacity of current
(4) Decision of installing location
(5) Installation of CVS-128 Display unit and transducer
(6) Installation of accessories
(7) Plan and execution of cable laying and connection
(8) Adjustment after completion of installation
Unpacking the configuration parts
Unpack the configuration items and confirm that all of the items match with the contents on the
equipment configuration list. If not matched, Contact the dealer you purchased or our sales company.
Inspection of configuration items and accessories
Inspect the appearance of each configuration item and accessories and check that no dents or
damage exist.
If any dents or damage exists and they are believed to be caused by accident during transportation,
contact the transportation and insurance company and consult our sales company or our dealer
nearest to you.
Decision of Installing Location
To exercise fully the performance of equipment, install the equipment, considering the points
mentioned below.
(1) Install the equipment at the location in the bridge so that its display can be easily seen.
(2) Select a safe location where the equipment is not exposed to humidity, water splash, rain and
direct sunshine.
(3) Keep enough space for maintenance. Especially, secure enough space at the rear panel where
many cables are concentrated.
(4) Keep the equipment as far away from the wireless transmitter/receiver as possible.
The equipment is not waterproofed. Avoid excessively damp place. Do not
install the equipment in place suffering from excessive water-drops.
Otherwise, the corrosion may occur inside.