Instruction manual

Chapter 5 Installation
CVS-128
5-10 0093112802-00
Connection of Transducer
At the end to the transmission/receiving cable for TD-500T-2B, TD-500T-3B and TD-501T-3B, a water
proof connector with 8-core is provided.
At the end to the transducer for TD-501C is plain.
1) TD-500T-2B/500T-3B/501T-3B
Connect to the J6 connector on the back of the receiver display unit.
2) TD-501-C
The user must have the cable, CW-840-0.3M (option)for the transducer.
Solder the transducer to CW-840-0.3M while referring to the table on connecting transducers.
After soldering is completed, please be sure to add water-resistance and insulation by applying
electrical tape (or other such tape) onto the soldered part of the cable.
Transducer Connection Table
Transducer Cable Transducer
2 lead shield wire number 2 lead shield wire color TD-501C
3 orange black
4 shield shield
5 white white
CW-840-0.3M
2 lead shield
3
TD1 (orange)
5 TD2 (white)
4
Shield
To Transducer
1
SPD.PULSE (blue)
2
SPD.VCC (purple)
8 SPD.GND (black)
6 TEMP.VCC (green)
7 TEMP.SIG (red)
To Speed Sensor
To Temperature Sensor
Lead wires