Output voltage in OFF state Uv - 2 V DC … Uv (max. voltage drop ≤ 2 V DC)
Output voltage in ON state ≤ 2 V DC
Table 24: Mechanical data
Dimensions (W x H x D) see "Safety switch dimensional drawings",
page 38
see "A
ctuator dimensional drawings",
page 38
see "Dimensional drawings of the mounting
bracket", page 38
Material
Safety switch housing
Ball br
ack
et
Latch plate of the actuator
Plug connector
Vistal® (fiberglass-reinforced thermoplastic)
St
ainless steel
Stainless steel
Stainless steel
Weight
Power to release safety switch 480 g
Power to lock safety switch 535 g
Flexible actuator 90 g
Rigid actuator 75 g
Mechanical service life 1 × 10
6
s
witching operations
Table 25: Ambient data
Enclosure rating IP 65 (IEC 60529)
IP 67 (IEC 60529)
IP 69K (IEC 20653)
Ambient oper
ating temperature –20 °C … +55 °C
Storage temperature –25 °C … +70 °C
Relative humidity 10 - 95% at 40 °C (IEC 60068)
Vibration resistance 1 mm / 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance 30 g, 11 ms (EN 60068-2-27)
EMC In accordance with IEC/EN 61326-3-1,
IE
C/EN 60947-5-2, IE
C/EN 60947-5-3 and
EN 300330
12.2 Connecting cables
Requirements for the connecting cables
Recommended c
able type = LIYY 8 x 0.25 mm² or 5 x 0.34 mm²
Maximum cable lengths
Table 26: Ma
ximum cable lengths
Number of safety
loc
k
in
g devices
Possible output cur‐
rent per OSSD (mA)
Possible output cur‐
rent AUX (mA)
Max. length of entire
cable from the last
safety locking device
to the controller (m)
4 100 50 10
5 5 5 8