Datasheet
PHOTOELECTRIC SENSORS | SICK 8015168/2016-02-22
Subject to change without notice
26
GR18S CYLINDRICAL PHOTOELECTRIC SENSORS
Mechanics/electronics
GRTB18S GRTE18S GRL18S GRL18SG GRSE18S
Supply voltage
1)
10 V DC ... 30 V DC
Ripple
2)
± 5 V
pp
Power consumption
≤ 30 mA
Output type
PNP / NPN (depending on type)
Output function
Complementary
Switching mode
Light switching
Dark switching
Light/dark switching
(depending on type)
Signal voltage
PNP HIGH/LOW V
S
- (≤ 3 V) / approx. 0 V
NPN HIGH/LOW Approx. V
S
/ ≤ 3 V
Switching frequency
5)
1,000 Hz 500 Hz ± 1,000 Hz 1,000 Hz
Connection type
Cable, 2 m
6)
Cable, 5 m
6)
Male connector,
M12
(depending on
type)
Cable, 2 m
6)
Male connector,
M12
(depending on
type)
Cable, 5 m
6)
Cable, 2 m
6)
Male connector,
M12
Cable with male
connector, M8,
300 mm
6)
(depending on
type)
Cable, 2 m
Male connector,
M12
(depending on
type)
Cable, 2 m
6)
Male connector,
M12
(depending on
type)
Circuit protection
A
7)
B
8)
D
9)
Protection class
III
Polarisation lter
–
l
–
Housing material
Plastic ABS
Metal Nickel-plated brass and ABS
Optics material
Plastic, PMMA
Enclosure rating
IP 67
Items supplied
Fastening nuts (2 x) Fastening nuts (2 x), Reector
P250 (depending on type)
Fastening nuts
(4 x)
EMC
EN 60947-5-2
Test input
– Sender OFF at
“Test” 0 V
Ambient operating temperature
10)
–25 °C ... +55 °C –25 °C ...
+55 °C
11)
–25 °C ...
+55 °C
Ambient storage temperature
–40 °C ... +70 °C
1)
Limit values when operated in short-circuit protected network: max. 8 A.
2)
May not exceed or fall below U
v
tolerances.
3)
At Uv > 24 V or ambient temperature > 49 °C, IA max. = 50 mA.
4)
Signal transit time with resistive load.
5)
With light/dark ratio 1:1.
6)
Do not bend below 0 °C.
7)
A = V
S
connections reverse-polarity protected.
8)
B = inputs and output reverse-polarity protected.
9)
D = outputs overcurrent and short-circuit protected.
10)
At U
v
<=24V and I
A
<50mA.
11)
Temperature stability following adjustment +/-10 °C.
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T