Operating instructions

Operating Instructions Chapter 5
ICR890
Electrical installation
8011325/0000/2006-10-24 © SICK AG · Division Auto Ident · Germany · All rights reserved 59
Note Please refer to the MSC800 Operating Instructions (no. 8011540) for connection to the
MSC800.
Note Please refer to the VMS410 Volume Measurement System Operating Instructions
(no. 8010592) for connection to the VMS410 or to the VMS 420/520 Volume
Measurement System Operating Instructions (no. 8010448) for connection to the
VMS420/520 as well as to the connector cap installation instructions for the VMS400/500
Volume Measurement Systems (no. 8010817).
No. MSC800
connection
Function Connection to ... Cable to be used
1 Power supply
input terminals
Power supply of the MSC800 Mains voltage 100 to 264 V AC/50 to 60 Hz Cable provided by the
client
2 TRIGGER Reading pulse trigger signals External reading pulse sensor Included in delivery
3 HOST or
ETHERNET or
PROFIBUS
Data output of the reading
result of all ICR890 Systems
via the MSC800
Host processor (RS 232, RS 422/485 or
Ethernet)
Cable provided by the
client
4 OUT 1/2 Indication of system status PLC (optional) Cable provided by the
client
5 AUX or
USB or
ETHERNET
Configuration/Diagnosis Standard PC, temporarily Cable provided by the
client
Tab. 5-5: ICR890 System with MSC800 (multi-side reading): Overview of the MSC800 connections which have to be established
No.
VMS4xx/5xx
connector cap
connection
Function Connection to ... Cable to be used
1 Power/CAN IN Communication with CAN bus
(CAN-SENSOR network)
“CAN 1-IN“ connection of the next ICR890
System
No. 6021164
(1 m (3.28 in))
No. 6021165
(3 m (9.84 ft))
No. 6021168
(5 m (16.4 ft))
4 Tacho Increment signals Incremental encoder (resolution 0.2 mm
(7.9 mil)/incr.)
Included in delivery