Operating instructions

Operating Instructions Chapter 6
ICR890
Operation
8011325/0000/2006-10-24 © SICK AG · Division Auto Ident · Germany · All rights reserved 85
Settings at the MSC800 for application of the ICR890 System as stand-alone device
(single-side reading)
Step Entry in the project tree Register tab
Parameter
1. Object Trigger Control Start/Stop of Object trigger Control
Start
2. MLG settings
3. Increment config. Increment Increment source
Resolution/Speed
4. 1D Code config. Symbologies Codabar
Code 39
UPC/EAN Familie
2/5 Interleaved
Code 93
Code 128 Familie
5. 2D Code config. Symbologies Data Matrix
PDF 417
6. Data processing Tracking Tracking mode
Object release point
7. Output Format Output Formating #1/#2
8. Network Architecture Master/Slave Network function
9. Serial Serial Host Interface Output format
Baudrate
Stopbits
Databits/Parity
Hardware
Protocol
Blockcheck
10. Serial Serial Auxilliary Interface Mode
11. Ethernet General IP-Address
IP-Mask
IP-Gate-Address
Speed
12. CAN CAN 1/2 Mode
Node-ID
Baudrate
Output format
13. Protokoll RDT400 RDT ID
Enable internal index telegram
14. Digital Outputs Output 1/2 Output 1/2
Inverted
Control
Duration
15. Digital Inputs Sensor 1/2 Control
Inverted
Debouncing
16. Realtime clock
Tab. 6-4: ICR890 System (stand-alone device) with MSC800: Overview of parameters which have to be set