Chapter 6 Operating Instructions
ICR890 High-end CCD Camera System
86 © SICK AG · Division Auto Ident · Germany · All rights reserved 8011325/0000/2006-10-24
Operation
Settings at the ICR890 System for application as stand-alone device without MSC800
Step Entry in the project tree Register tab
Parameter
1. Reading config. Codelabel properties Minimum code position
Maximum code position
Symbol Contrast
2. Reading config. Image capturing properties Digital zoom
Image Resolution
3. Object Trigger Control Start/Stop of Object trigger Control
Start
4. Focus Control Optionen Fokussteuerung Default Position
Focus Control Mode
5. Focus Control Distance Measurement Source MLG
VMS
6. Lamp Control Illumination mode Lamp on
Lamp timeout active
Timeout
7. Position Offsets X-Offset
Y-Offset
Z-Offset
8. Position Coordinates X-Coordinate
Y-Coordinate
Z-Coordinate
Distance to deflecting mirror
9. Position Angles Alpha
Beta
Gamma
10. Increment config. Increment Increment source
Resolution/Speed
11. Image Acquisition Request Request
Image format
Bitmap scaling/JPEG Quality
Activate Diagnosis Output
Output limited by code position
12. 1D Code config. Symbologies Codabar
Code 39
UPC/EAN Familie
2/5 Interleaved
Code 93
Code 128 Familie
13. 2D Code config. Symbologies Data Matrix
PDF 417
14. Data processing Tracking Tracking Mode
Object release point
15. Output Format Output Formating #1/#2
16. Network Architecture Master/Slave Network function
17. Serial Serial Host Interface Output format
Baudrate
Stopbits
Databits/Parity
Hardware
Protocol
Blockcheck
18. Serial Serial Auxilliary Interface Mode
Tab. 6-5: ICR890 System (stand-alone device) without MSC800: Overview of parameters which have to be set