Online data sheet LFP2000-A4NMB LFP Cubic LEVEL SENSORS
LFP2000-A4NMB | LFP Cubic LEVEL SENSORS A B C D E F H I J K L M N O P Q R S T Ordering information Type Part no. LFP2000-A4NMB 1057091 Other models and accessories www.sick.com/LFP_Cubic Illustration may differ Detailed technical data Features Medium Fluids Measurement Switch, Continuous Design Standard Probe type Rod probe Probe length 2,000 mm Process pressure –1 bar ... 10 bar Process temperature –20 °C ...
LFP2000-A4NMB | LFP Cubic LEVEL SENSORS Deactivated area at end of probe ≥ 10 mm 1) MTTF 194.3 years (EN ISO 13849-1) 1) 2) With water under reference conditions. With parameterized container with water under reference conditions, otherwise 40 mm. Electronics Supply voltage 12 V DC ... 30 V DC 1) Power consumption ≤ 100 mA at 24 V DC without output load Initialization time ≤5s Protection class III Connection type Round connector M12 x 1, 5-pin Output signal 4 mA ... 20 mA, 0 V ...
LFP2000-A4NMB | LFP Cubic LEVEL SENSORS ECl@ss 8.0 27371813 ECl@ss 8.1 27371813 ECl@ss 9.0 27371813 ETIM 5.0 EC001447 ETIM 6.0 EC001447 UNSPSC 16.0901 41113710 Dimensional drawing (Dimensions in mm (inch)) Dimensional drawing: rod probe 15 (0.59) 22 (0.87) 43 (1.69) M12x1 IA G 3/4 A 3/4" NPT IA 5 (0.20) 32 (1.26) 22 (0.87) 71 (2.80) 36 (1.42) G 3/4 A 3/4" NPT M M L L 7 0.28) monoprobe ① ② ③ ④ 4 ( 20 0.79) IAE ( IAE H I J K L M N O P Q R S T 126 (4.96) 33 (1.
LFP2000-A4NMB | LFP Cubic LEVEL SENSORS Connection type 2 3 5 1 4 ① ② ③ ④ ⑤ L+: Supply voltage, brown QA: Analog current-/voltage output, white M: Ground, reference ground for current-/voltage output, blue C/Q1: Switching output 1, PNP/IO-Link-communication, black Q2: Switching output 2, PNP/NPN, grey Instruction for installation Mono rod probe mounted in metal tank M = Measuring range X = Inactive area at probe end No measurement possible Rope probe mounted in metal tank Installation in nozzle: D
LFP2000-A4NMB | LFP Cubic LEVEL SENSORS H I J K L M N O P Q R S T Installation in a metal immersion tube or metal bypass D ≥ DN 40 Distance tank wall/tank bottom: B ≥10 mm (0.
LFP2000-A4NMB | LFP Cubic LEVEL SENSORS Installation in a metal tank Unit with mono probe mounted in metal tank Installation in nozzle: D >= DN 25 (1") Distance tank wall/tank bottom: A >= 50 mm (1.97") B >= 10 mm (0.40") Distance to other tank fittings >= 100mm (3.
LFP2000-A4NMB | LFP Cubic LEVEL SENSORS A B C D E F H I J K L M N O P Q R S T Brief description 8 Type Part no. Coaxial tube for LFP with process connection G 3/4, process connection of coaxial tube 3/4" NPT, material 1.4571/316TI, for probe length 400 mm LFPCT-0400N1 2068167 Coaxial tube for LFP with process connection G 3/4, process connection of coaxial tube G 3/4, material 1.
LFP2000-A4NMB | LFP Cubic LEVEL SENSORS Brief description Type Part no. Coaxial tube for LFP with process connection G 3/4, process connection of coaxial tube 3/4" NPT, material 1.4571/316TI, for probe length 1700 mm LFPCT-1700N1 2068180 Coaxial tube for LFP with process connection G 3/4, process connection of coaxial tube G 3/4, material 1.
LFP2000-A4NMB | LFP Cubic LEVEL SENSORS A B C D E F H I J K L M N O P Q R S T Brief description Type Part no.
Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements.