Datasheet
FLUID SENSORS | SICK8013162/2017-11-20
Subject to change without notice
5
PRESSURE SENSORS PBS
Type code
Pressure type
R Gauge
A Absolute
C Compound
Pressure unit
B bar
M MPa
P psi
K kg /cm
2
Measuring range (see below)
Process connector
GE G ½ B, EN 837
G1 G ¼ A, DIN 3852-E
G2 G ¼ female
GH G ¼ female for Ermeto
N1 ¼” NPT
M2 M20 x 1.5
R1 R ¼ ISO 7, DIN 2999
F2 G ½ B ush-mounted
Pressure port
S Standard pressure port
N 0.3 mm pressure port
M 0.6 mm pressure port
F Flush-mounted membrane
Seal
N NBR
F FPM/FKM
C Copper
S Stainless steel
0 Without seal
Output signal
A 2 x PNP
B 1 x PNP + 4 …20 mA
C 1 x PNP + 0 … 10 V
D 2 x PNP + 4 … 20 mA
E 2 x PNP + 0 … 10 V
F 2 x NPN
G 1 x NPN + 4 … 20 mA
H 1 x NPN + 0 … 10 V
I 2 x NPN + 4 … 20 mA
K 2 x NPN + 0 … 10 V
L IO-Link/PNP + PNP
M IO-Link/PNP + NPN
N IO-Link/PNP + 4 … 20 mA
P IO-Link/PNP + 0 … 10 V
Q IO-Link/PNP + PNP + 4 … 20 mA
R IO-Link/PNP + PNP + 0 … 10 V
S IO-Link/PNP + NPN + 4 … 20 mA
T IO-Link/PNP + NPN + 0 … 10 V
Electrical connector
M M12 x 1, 4-pin
5 M12 x 1, 5-pin
Design specics
Z Without design specics
G Free from oil and grease
PBS - S S A O
Not all variations of the type code can be combined! Not all available variations are shown.
Measuring range
Gauge Pres-
sure
Overpressure
safety
Absolute
Pressure
Overpressure
safety
Compound
Pressure
Overpressure
safety
1X0 0 … 1 bar 2 bar 1X0 0 … 1 bar abs 2 bar abs 1X0 –1 ... 0 bar 2 bar
1X6 0 … 1,6 bar 3,2 bar 1X6 0 … 1,6 bar abs 3,2 bar abs 2X5 –1 ... +1,5 bar 3 bar
2X5 0 … 2,5 bar 5 bar 2X5 0 … 2,5 bar abs 5 bar abs 4X0 –1 ... +3 bar 6 bar
4X0 0 … 4 bar 8 bar 4X0 0 … 4 bar abs 8 bar abs 6X0 –1 ... +5 bar 10 bar
6X0 0...6 bar 12 bar 6X0 0 … 6 bar abs 12 bar abs 010 –1 ... +9 bar 18 bar
010 0 … 10 bar 20 bar 010 0 … 10 bar abs 20 bar abs 016 –1 ... +15 bar 30 bar
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T