Test report no. 18011525 EUT: RFH630-1102101S05 Page 1 of 1 FCC ID: WRMRFH630 FCC Title 47 CFR Part 15 Date of issue: 2018-12-05 Annex acc. to FCC Title 47 CFR Part 15 relating to Sick AG RFH630-1102101S05 Annex no. 5 User Manual Functional Description Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators ANSI C63.4-2014 ANSI C63.10-2013 Date: 2018-06-06 Created: P4 TÜV NORD Hochfrequenztechnik GmbH & Co.
en QUICKSTART RFH6xx RFID read/write device (HF) with internal short range antenna RFH630-1102101S05 For simplicity in this document, the RFH630-1102101S05 read/write device is referred to as the “device”. About this document The purpose of this Quickstart is to allow you to commission the device quickly and easily, and to achieve initial read results with transponders.
antenna gain, the integrated transponder IC, and its associated sensitivity. Important! A successful reading/writing can only be guaranteed if the transponder is orientated plan parallel the to the antenna and in the middle of the read/write device. • The power supply via a power supply unit must be capable of buffering a brief power failure of 20 ms. • All circuits connected to the device must be designed as ES1 circuits.
c. Accessing the data on a transponder Device description 1. In order to access the memory area of a transponder, click the Stop button in Quickstart. 2. Highlight the desired transponder (click it with the mouse). 3. Click the Transponder Access button. The Transponder User Data tab displays the content of the selected transponder.
NOTE Risk of data loss or irreparable damage to the memory card! The device does not signal the respective access to the card used (read/write). ¾¾ If the parameter set is saved with the option “Save parameter permanently” in the device using SOPAS ET, do not remove the memory card during the process and do not switch off the supply voltage. Technical data (excerpt) Type RFH630-1102101S05 Product category ISO/IEC-15693 compatible read/write unit Carrier frequency Air interface protocol HF (13.
Device layout 2 100 (3.94) 1 147 (5.79) Repairs 30 (1.18) 12.5 (0.49) Repair work on the device may only be performed by qualified and authorized service personnel from SICK AG. 100 (3.94) Transport and store the device in the original packaging, with protective plugs and caps fully screwed on. Do not store outdoors. To ensure that any residual moisture present can escape, do not store the device in airtight containers. Do not expose to any aggressive substances.
Overview of all interfaces and connection options Overview of pin assignments Serial CDB620-001 (optional) 1 2 Connection "Ethernet" "Serial RS-232" (Aux 1), alternative to Ethernet Aux port Null modem cable (female connector, D-Sub, 9-pin / female connector, D-Sub, 9-pin), TxD and RxD crossed 3 4 CMC600 ... ... RFH630-1102101S05 GND VS VS SOPAS PC "Ethernet" (Aux 2) External antenna (optional), e.g.
(Blank page) 8023443/11W0/2018-11-20 • Subject to change without notice • SICK AG • Waldkirch • Germany • www.sick.com 8023443-11W0_QS_RFH630-1102101S05_EN_201801120_final.indd 7 RFH6xx | SICK 7 23.11.
8023443/11W0/2018-11-20 • Subject to change without notice • SICK AG • Waldkirch • Germany • www.sick.com 8023443-11W0_QS_RFH630-1102101S05_EN_201801120_final.indd 8 8023443/11W0/2018-11-20 • 8M_TM • Printed in Germany • All rights reserved • Subject to change without notice (Blank page) RFH6xx | SICK 8 23.11.