User's Manual

RFI341 Radio Frequency Interrogator
19 SICK AG Division Auto Ident - Germany - All rights reserved 8012640/2008-03-10
3.2 Functional Description of the device
The device operates according the reader/interrogator “talks first” (ITF)
method as defined in the ISO/IEC 15693 Standard. Each transponder in
the field remains silent until a request is received. The interrogator can
identify simultaneously a number of tags present in the antenna field. The
interrogator can write data to and read data from the transponders.
Transponders can be addressed by e.g. using the factory programmed,
unique read only number (64 bit length). If the data in the user memory of
the tag are not write protected, the read/write feature enables the
rewriting of the data stored in this memory.
The RFI341 is controlled by the data interface. The commands are
described in the document “Telegram Listing RFI341” which enables the
use of the features defined in ISO/IEC 15693. Additional commands
support the use of sensor inputs and/or actuators. After configuration the
device could either work in a mode where the host in controlling the unit
or in trigger mode. Configuration in trigger mode means: The device is
waiting for a start condition to start reading automatically. Reading results
will be transmitted directly or with closing the read window. If the device
is running in background mode only a valid escape sequence will
terminate this and brings the device back in command mode (see also
telegram listing).
To start a reading process, when an object with a transponder is in the
field, the RFI341 must be clocked by one of the following:
A command sequence via the data interface
The execution (based on a suitable trigger) of a previously
defined background command
If a transponder is detected, the relevant data can be send via the data
interface to the host. The “Data LED” indicates the presence of tag data.
Product Description