User's Manual

RFI341 Radio Frequency Interrogator
24 SICK AG Division Auto Ident - Germany - All rights reserved 8012640/2008-03-10
5. Electrical Installation
5.1 Overview of the Installation Steps
Connect the RFI341 with the Antenna
Connect the sensors to the RFI341 inputs (if used)
Connect the actuators to the RFI341 outputs (if used)
Connect the PC or Profibus data interface of the RFI341
Connect the power supply to the RFI341
5.2 Electrical Connections (basic version)
The electrical connections of the RFI341 consist of:
Socket for the RFA3xx antenna connection
Mux-Control interface
PG’s for cable connections for:
o Two galvanic separated switching input terminals with each a
separate reference
o Two switching outputs - 24 V DC in reference
o Three terminals for the RS 232 data interface, Ethernet RJ45
plug
o Two terminals for the main supply (24V DC) and Terminals for
grounding (PE)
See 5.4.5 / 5.4.6 for In- Output connections
Electrical Installation
RXD In
TXD out
GND
VS
GND
Out 1
GND
OUT 2
GND
IN 1
GND 1
IN 2
GND 2
+24V in
GND
Ethernet
FUSE 2A/T Power switch