5.3 Electrical Connections (M12 connectivity version)
The M12 Connectivity Version consist out of one PG plug for e.g. Ethernet
and M12 plugs for power, RS232, Output and 2 for the Trigger Input. The
individual pinning could be found on a sticker that is placed inside the device
door.
5.4 Preparations for Electrical Installation
5.4.1 Requirements for the RS-232 HOST interface
The host interface can be operated as a RS 232 data interface. The
maximum cable lengths are a function of the selected data transfer rate:
To prevent interference, do not lay the cable parallel to the mains supply and
motor cables over long distances, e.g., in cable ducts.
5.4.2 Requirements for the Profi-Bus interface
The Bus termination is realised with 3 resistors mounted at the terminals. If a
device is not the last station in a Profi-Bus network those resistors have to be
removed. The shielding need to be fixed with the available shielding
brackets at the PG glands.