User's Manual

RFI341 Radio Frequency Interrogator
33 SICK AG Division Auto Ident - Germany - All rights reserved 8012640/2008-03-10
6.3.3 Oscillator Switch off delay
Switching off the HF-field results in a power-on reset of all tags present in the
reader field. The length of time set should be checked very carefully. In the
worse case scenario, the tags which are in the selected or quiet mode will
loose this status. Depending on the application, it could be necessary to set
this time to a lower value. The factory default setting is 500 ms.
6.3.4 Read after Write Verify
The interrogator can be set so that it will automatically execute a read after
write if data is written to the transponder. This requires some time and the
user can define whether or not he wants to receive this verification. The
factory default setting is set “ON”.
6.3.5 HF Reset for Inventory Commands
Setting this feature to “ON” results in a HF reset before an inventory
command is executed. The factory default setting is “ON”.