9. Technical Data
9.1 RFI341-1503
Type RFI341 Host/Data Interface
Protocol STX/ETX (see document “ RFI341
Telegram Listing 8011237 ”)
Terminal data interface RS-232 9,600 baud to 115kbaud, start, stop, no
parity (8N1)
Ethernet TCP/IP - 10/100Mbit
RF Interface Carrier Frequency 13.56 MHz
(13.553 to 13.567 MHz)
RF output power (max) 4 W (±1 dB)
Switching Inputs Vin
high
max = 30 V,
Vin
high
typ = 24 V,
Vin
high
min = 18 V,
Vin
low
max = 1,5 V
Iin
max
< 4mA
Switching Outputs Vout = Vin (power supply) – <=1V
Iout max = 400mA restive load ; short cut
and overload protected
Mains power supply Operating Voltage 24V DC (20..29V);
- slope time < 3 sec
- start up time < 4 sec.
Supply Current < 2,0A
Protection Class 3
Mechanical
Housing (dimensions) except stainless
steal where the with is 210mm instead of
200mm
300 mm x 200 mm x 120 mm
(15.8 in x 7.9 in x 4,7 in)
Antenna Connector BNC (standard and M12 version)
TNC (stainless steel version)
Enclosure rating / protection class IP65 (standard and M12 version)
IP66 (stainless steel version)
Operation temperature -20 °C to 50 °C
Storage temperature -20 °C to 60 °C (-4 °F to 142 °F)
Colour SICK blue RAL5012 (standard an M12
Version)
Without paint (stainless steel version)
Mechanic IEC 60068-2-64 (10..500 Hz;1 grms)
Technical Data