User's Manual

RFI341 Radio Frequency Interrogator
44 SICK AG Division Auto Ident - Germany - All rights reserved 8012640/2008-03-10
In this case, the interrogator will skip to the next slot. Within the next
inventory session, these transponders will participate whereas those that
have been successfully read (UID) could be not present – depending on the
function, which may set these transponders to the quiet stage. This process
could be repeated until all transponders are identified. Tags colliding in a slot
could be separated with masks according to ISO Standard.
Command Codes
The ISO 15693 requires that only two commands to be mandatory in an IC.
These are “Inventory and Stay quiet”. All other commands are defined but
optional.
Therefore, ensure that the tag used supports the application requirements.
These include:
• Read and write feature
• Lock block feature
• Read and write of multiple blocks
• AFI and DSFID features