Datasheet
Scanning range, typ. max./on reflector 22 m/on PL 80 A
Sensitivity Adjustable
Light source
1)
, light type LED; red light
Light spot diameter Approx. 250 mm at 15 m
Supply voltage V
S
10 to 30 V DC
2)
Residual ripple
3)
< 5 V
PP
Current consumption
4)
≤ 50 mA
Swiching outputs PNP or NPN, Q or Q
–
Output current I
A
max. 100 mA
Response time
5)
≤ 500 μs
Max. switching frequency
6)
1000/s
VMA contamination signalling output Alarm, PNP
Time delay Adjustable, 0.5 to 10 s
Test input »TE« Sender switched off
Sender off PNP or NPN: TE to 0 V
Connection type M16 screw fixing
Plug
VDE protection class
7)
Circuit protection
8)
A, B, C
Enclosure rating IP 67
Ambient temperature Operation –40 °C to +60 °C
Storage –40 °C to +75 °C
Weight Approx. 140 g
Polarisation filter
Housing material ABS
Technical data WL 34-
1)
Average service life 100,000 h
at T
A
= +25 °C
2)
Limit values
3)
May not exceed or fall short of V
S
tolerances
4)
Without load
5)
Signal flight time with ohmic load
6)
With light/dark ratio 1:1
7)
Withstand voltage 50 V DC
8)
A= V
S
connections reverse-polarity
protected
B = Outputs Q and Q
–
short-circuit
protected
C = Interference pulse suppression
V 230 V 240 B 430 B 440 V 530 V 540
Order information
Type
WL 34-V 230
WL 34-V 240
WL 34-B 430
WL 34-B 440
WL 34-V 530
WL 34-V 540
Order no.
1 019 243
1 019 244
1 019 245
1 019 246
1 019 247
1 019 248
1
6
7
4
5
3
2
(m) 5 10 15 20 25
100
10
1
Operating reserve
Scanning range
typ. max.
Operating range
WL 34 Red Light
Reflector type Operating range
1
2
3
4
5
0 (m) 2416 201284
0.03 15 22
0.03 11
0.03 11
Operating range Typ. max. scanning range
Tastbereich auf Grau
2
PL 50 A 0.03 to 11 m
3
PL 40 A 0.03 to 11 m
4
PL 30 A 0.03 to 7 m
5
PL 20 A 0.03 to 7 m
6
Diamond Grade
(20 cm x 20 cm)
0.3 to 7 m
7
C 110 0.15 to 10 m
1
PL 80 A 0.03 to 15 m
16
16
0.03 7
10
0.03 7
6
7
0.3 7
0.15 10
10
10
13
Scanning range and operating reserve
WL 34
885
05-08-2006 SENSICK CATALOGUE
KD01_W34_en.qxd 13.07.2006 16:24 Uhr Seite 885