Datasheet
2010-03-03 SICK 21
Subject to change without notice
W12-3
Technical data
WTB12-3 N2413 P2413
Scanning distance typ. max.
20 ... 600 mm
1)
Operating distance
20 ... 600 mm
1)
Adjustment of operating distance Teach-in: double teach button
Light source, light type
LED, Infrared light, 850 nm
2)
Light spot diameter Approx. 15 x 15 mm at 200 mm distance
Supply voltage V
s
DC 10 ... 30 V
3)
Ripple
≤
5 V
pp
4)
Power consumption
≤
55 mA
5)
Switching outputs
NPN antivalent
PNP antivalent
Signal voltage PNP HIGH/LOW > V
s
- 2.5 V/approx. 0 V
Signal voltage NPN HIGH/LOW Approx. > V
s
/< 2.5 V
Output current I
a
max 100 mA
Response time
≤
330
µ
s
6)
Switching frequency 1,500 Hz
7)
Connection type
Connector, M12, 4-pin
VDE protection class
8)
Circuit protection
V
s
connections reverse-polarity protec-
ted/All outputs short-circuit protected/
Interference suppression
Enclosure rating
IP 66, IP 67
Ambient temperature operation
–40
°
C ... +60
°
C
Ambient temperature storage
–40
°
C ... +75
°
C
Weight
Approx. 120 g
Housing material
Zinc die-cast
9)
1)
Object with 90 % remission (based on
standard white to DIN 5033)
2)
Average service life 100,000 h at
T
a
= +25 °C
3)
Limit values, operation in short-circuit
protected network max. 8 A
4)
May not exceed or fall short of V
s
tolerances
5)
Without load
6)
Signal transit time with resistive load
7)
Typ. max. value with light/dark ratio 1:1
8)
Reference voltage 50 V DC
9)
Teflon-coated housing available on
request
Order information
Type Order no.
WTB12-3N2413 1041428
WTB12-3P2413 1041423
1. Position the object in the path of the beam.
2. Press both buttons simultaneously (for approx. 2 seconds) until the yellow LED flashes = object in focus.
In the event of button activation of less than 2 seconds, the Teach command is not effective, therefore providing no protection against further unwanted
manipulation.
3. Release buttons; yellow LED illuminates continuously = object is positively detected.
4. Fine adjustments can be made to the scanning distance, when required by the application: Pressing the "+" button (approx. 0.5 sec) = scanning distance will
be increased. Pressing the “–” button (approx. 0.5 sec) = scanning distance will be decreased. In the event of button activation less than 0.5 sec, no change
to the scanning distance is made. Upon activation of the button, the yellow LED flashes.
5. The Teach-in scanning distance is stored in the memory.
Teach-in procedure via double-teach button
3
Scanning on white, 90 % Remission
2
Scanning distance on grey, 18 % Remission
Scanning distance on black, 6 % Remission
1
20 400
20 500
20
600
3
2
1
0 (mm) 100 200 300 400 500 600
3
1
2
5
10
15
20
25
% of scanning distance
6%/90%
18%/90%
90%/90%
(mm) 100 200 300 400 500 600
Scanning distance
DB_W12_3_en.fm Seite 21 Donnerstag, 25. März 2010 1:51 13