Datasheet
2010-03-03 SICK 5
Subject to change without notice
W12-3
Technical data
WTF12-3 N2433 P2433
Scanning distance typ. max.
30 ... 175 mm
1)
Operating distance
30 ... 175 mm
1)
Adjustment of operating distance Teach-in: double teach button
Light source, light type
LED, Red light, 640 nm
2)
Light spot diameter Ø 2.0 mm at 60 mm distance
Supply voltage V
s
DC 10 ... 30 V
3)
Ripple
≤
5 V
pp
4)
Power consumption
≤
45 mA
5)
Switching outputs
NPN antivalent
PNP antivalent
Signal voltage PNP HIGH/LOW > V
s
- 2.5 V/approx. 0 V
Signal voltage NPN HIGH/LOW Approx. > V
s
/< 2.5 V
Output current I
a
max 100 mA
Response time
≤
330
µ
s
6)
Switching frequency 1,500 Hz
7)
Connection type
Connector, M12, 4-pin
VDE protection class
8)
Circuit protection
V
s
connections reverse-polarity protec-
ted/All outputs short-circuit protected/
Interference suppression
Enclosure rating
IP 66, IP 67
Ambient temperature operation
–40
°
C ... +60
°
C
Ambient temperature storage
–40
°
C ... +75
°
C
Weight
Approx. 120 g
Housing material
Zinc die-cast
9)
1)
Object with 90 % remission (based on
standard white to DIN 5033)
2)
Average service life 100,000 h at
T
a
= +25 °C
3)
Limit values, operation in short-circuit
protected network max. 8 A
4)
May not exceed or fall short of V
s
tolerances
5)
Without load
6)
Signal transit time with resistive load
7)
Typ. max. value with light/dark ratio 1:1
8)
Reference voltage 50 V DC
9)
Teflon-coated housing available on
request
Order information
Type Order no.
WTF12-3N2433 1041409
WTF12-3P2433 1041405
1. Position the background in the path of the beam.
2. Press both buttons simultaneously (for approx. 2 seconds) until the yellow LED flashes = background in focus.
In the event of button activation of less than 2 seconds, the Teach command is not effective, therefore providing no protection against further unwanted
manipulation.
3. Release buttons; yellow LED illuminates continuously = background is positively detected.
4. Fine adjustments can be made to the scanning distance, when required by the application: Pressing the "+" button (approx. 0.5 sec) = scanning distance will
be increased. Pressing the “–” button (approx. 0.5 sec) = scanning distance will be decreased. In the event of button activation less than 0.5 sec, no change
to the scanning distance is made. Upon activation of the button, the yellow LED flashes.
5. The Teach-in scanning distance is stored in the memory.
Teach-in procedure via double-teach button
3
Scanning distance on white, 90 % Remission
2
Scanning distance on grey, 18 % Remission
Scanning distance on black, 6 % Remission
1
30 125
30 150
30 175
3
2
1
0 (mm) 40 80 120 160 200
3
1
2
-8
-7
-6
-5
-4
-3
-2
-1
0
% of scanning distance
6%/90%
18%/90%
90%/90%
(mm) 40 80 120 160 200
Scanning distance
DB_W12_3_en.fm Seite 5 Donnerstag, 25. März 2010 1:51 13