Operation Manual
5
Installation
17 Connect in accordance with the
terminal diagram.
18 Wiring diagram with CTÖ 602-0.
19 For each call button, a maximum
of two in-house telephones can be
connected. Connection of a storey
call button (ERT) is only possible
with the storey call button accessory
ZERT811-…
Terminal assignment CA812-…
1, 7… System line 1+n
b, c Power supply 12VAC
Tö Relay contact door release
Li Relay contact light
D+, D- CTÖ602-…/SFC602-…
control
Terminal assignment TR 603-…
b, c Power supply 12VAC
L1, N Power connection
Terminal assignment HTS811-…
1, 7 System line 1+n
ERT Storey call button
Range
Range from the transformer to the
door station max. 50m, transformer
to the in-house telephone 400m
with 0.8mm conductor material.
When operating 2 in-house tele-
phones in parallel, the range reduces
to 200m.
*) Using the light button in the in-
house telephones HTS811-… the
light contact in the door loudspeaker
is closed for 0.8 seconds. The refer-
ence for this contact is terminal c,
pick-off at terminal Li. Following
completion of the installation, this
function is active without any further
programming. To actuate the stair-
case and/or outside light, according
to VDE regulations a light current
relay or time relay (e.g. ZR502-…)
must be interconnected. Contact
load max. 15VAC, 30VDC,
switching time 0.8 seconds.
In parallel to an in-house telephone,
the secondary signal controller
NSC602-… can be connected, e.g.
for actuation of a radio chime. The
NS711-… can be operated as an
additional signalling unit in parallel
at an HTS811-…
It is not possible to connect other
devices such as a DCA612-… or
HTC811-…
Lettering
20 Open the nameplate from the
outside, for example using a at
bladed screwdriver, and carefully
remove the inscription insert. To
insert the nameplate, lock into place
by exerting light pressure.
21 Info sign from the inside, e.g.
open using at blade screwdriver
and remove inscription eld. To
insert, clip in the info sign exerting a
slight pressure.
Troubleshooting
The transformer is tted with a
thermal fuse on the primary side.
After short circuit or overload
• Disconnect the device from the
power supply for appr. 1 min.
• Remedy the fault.
• Restore the mains power.
Specications CA812-…
Contact type: n.o. contact 24V, 2A
Protection system: IP54
Ambient temperature:
–20°Cto+55°C
Dimensions (mm) WxHxD:
82x226x33
Specications TR603-…
Operating voltage: 230VAC,
+/-10%, 50/60Hz
Output voltage: 12VAC
Output current: max.1.3A
Fusing:
Secondary side with thermal fuse
Protection system: IP30
Ambient temperature:
0°Cto+40°C
Horizontal pitch (HP): 3
Dimensions (mm) WxHxD:
53.5x89x60
Specications HTS811-…
Dimensions (mm) WxHxD:
91x201x46