User's Manual

Table Of Contents
Dimension drawings
12.9 Raised-Face flange per EN 1092-1 for flanged horn antenna
SITRANS LR250 (PROFIBUS PA)
Operating Instructions, 01/2014, A5E32221386-AB
193
Raised-Face flange dimensions
Pipe size
Flange bolt
hole pattern
Flange
O.D.
(mm)
Bolt hole
circle Ø
(mm)
Bolt hole Ø
(mm)
No. of bolts
Angle of
adjacent
bolt holes
Facing Ø
(mm)
Thickness
(mm)
DN 50
PN 10/PN 16
165
125
18
4
90
102
18
DN 80
PN 10/PN 16
200
160
18
8
45
138
20
DN 100
PN 10/PN 16
220
180
18
8
45
158
20
DN 150
PN 10/PN 16
285
240
22
8
45
212
22
DN 50
PN 25/PN 40
165
160
18
4
90
138
20
DN 80
PN 25/PN 40
200
160
18
8
45
138
24
DN 100
PN 25/PN 40
235
190
22
8
45
162
24
DN 150
PN 25/PN 40
300
250
26
8
45
218
28
Raised-Face flange markings
Blind Flange Markings (Optional
Manufacturer’s Logo [optional]; Flange
Standard; Nominal Size; Material; Heat
Code)
Machining Identification
Welded Assembly Identification
a)
Serial no.
Logo
Flange series
Flange
series
Heat Code
no.
Facing
Manufacturer’s logo; EN 1092-1 05 ‘B1’;
‘DN50’ ‘PN16’ ‘1.4404 or 1.4435’
A1B2C3
mmddyyx
xx
xxxxx xxxxx A1B2C3 RF
a)
When flange material is alloy N06022/2.4602, additional material and heat code identification
is provided.
The flange markings are located around the outside edge of the flange.
Serial number:
a unique number allotted to each flange, including the date of manufactur
e
(MMDDYY) followed by a number from 001 to 999 (indicating the sequential
unit produced).
Flange series:
the Siemens Milltronics drawing identification.
Heat code:
a flange material batch code identification.