User's Manual

Table Of Contents
Dimension drawings
12.3 Flanged horn antenna
SITRANS LR250 (PROFIBUS PA)
Operating Instructions, 01/2014, A5E32221386-AB
183
Flanged Horn dimensions
Nominal horn
size
in mm (inch)
Horn O.D.
in mm (inch)
Height to sensor reference point, in mm
(inch)
a)
Beam angle
(°)
b)
Measurement range,
in m (ft)
Stainless steel flange:
raised or flat-face
Optional alloy
flange
c)
50 (2)
47.8 (1.88)
135.3 (5.32)
138.3 (5.44)
15
20 (65.6)
80 (3)
74.8 (2.94)
168.3 (6.62)
171.3 (6. 74)
10
100 (4)
94.8 (3.73)
223.3 (8.79)
226.3 (8.90)
8
a)
Height from bottom of horn to sensor reference point as shown: see Flanged horn antenna with
extension (Page 184). See also Raised-Face flange per EN 1092-1 for flanged horn antenna
(Page 192), or Flat-Face flange (Page 197).
b)
-3dB in the direction of the polarization axis (see Polarization reference point (Page 20) for an
illustration).
c)
Optional alloy N06022/2.4602 (Hastelloy
®
C-22 or equivalent). See Raised-Face Flange
Dimensions (Page 192).
Note
Heights to sensor reference point are for stainless steel flanges. For optional alloy
N06022/2.4602 (Hastelloy
©
C-22 or equivalent) see Flanged Horn dimensions above.