User's Manual
Table Of Contents
- Table of Contents
- SITRANS LR250 Overview
- Specifications
- Installation
- Wiring
- Operating via the handheld programmer
- Operating via SIMATIC PDM
- Functions in SIMATIC PDM
- Quick Start Wizard via SIMATIC PDM
- Changing parameter settings using SIMATIC PDM
- Parameters accessed via pull-down menus
- Operating via AMS Device Manager
- Functions in AMS Device Manager
- Features of AMS Device Manager
- Device Description (DD)
- Configuring a new device
- Startup
- Pull-down menu access
- Device configuration
- Quick Start Wizard via AMS Device Manager
- Maintenance and Diagnostics
- Remaining Device Lifetime [see Remaining Device Lifetime (4.2.) on page 99]
- Remaining Sensor Lifetime [see Remaining Sensor Lifetime (4.3.) on page 102]
- Service Schedule [see Service Schedule (4.4.) on page 105]
- Calibration Schedule [see Calibration Schedule (4.5.) on page 108]
- Electronic Temperature
- Wear (see Wear on page 56)
- Communication
- Security
- Device Diagnostics
- AMS Menu Structure
- Functions in AMS Device Manager
- Parameter Reference
- 1. Quick Start
- 2. Setup
- 3. Diagnostics
- 4. Service
- 5. Communication
- 6. Security
- 7. Language
- Appendix A: Alphabetical Parameter List
- Appendix B: Troubleshooting
- Appendix C: Maintenance
- Appendix D: Technical Reference
- Principles of Operation
- Echo Processing
- Analog Output
- Maximum Process Temperature Chart
- Process Pressure/Temperature derating curves
- Loop power
- Appendix E: Application Examples
- Appendix F: HART Communications
- Appendix G: ATEX Certificates
- Appendix H: Firmware Revision History
- Glossary
- Index
- LCD menu structure
Page 138 SITRANS LR250 (HART) – INSTRUCTION MANUAL 7ML19985JE03
mmmmm
D: Technical Reference
DN50, DN80, DN100, and DN150 Flanged Versions: PN16
DN50, DN80, DN100, and DN150 Flanged Versions: PN40
WARNING: Never attempt to loosen, remove or disassemble process
connection or instrument housing while vessel contents are under
pressure.
Note: Customer to provide adequate bolting and gasketing to retain vessel pressure and
provide sufficient sealing.
Process Connection Series:
• 51242 or 51252 series flange.
• Ensure your instrument has
the Process Identification
Tag showing one of this
series, and 25547, 25581,
25656, or 25657 stamped on
flange.
PN16
pressure (bar, gauge)
process temperature (°C)
Process Connection Series:
• 51242 or 51252 series
flange.
• Ensure your instrument
has the Process
Identification Tag showing
one of this series, and
25547, 25581, 25656, or
25657 stamped on flange.
process temperature (°C)
PN40
pressure (bar, gauge)