User's Manual

Table Of Contents
7ML19985JE03 SITRANS LR250 (HART) – INSTRUCTION MANUAL Page 23
mmmmm
Installation
Joints (if unavoidable) must be machined to ± 0.25 mm (± 0.010”) and must have a
welded connecting sleeve on the outside.
Bypass vent required at the upper end of the bypass
1)
Device orientation
Installation Instructions
Threaded Version
1. Before inserting the device into its mounting connection, check to ensure the
threads are matching, to avoid damaging them.
2. Simply screw the device into the process connection, and hand tighten, or use a
wrench. A torque of 40 N m (30 ft.lbs) is recommended
Flanged Version
See
Flanged Horn with extension
on page 14,
Raised-Face Flange per EN 1092-1
on page
16, and
Flat-Face Flange
on page 17, for dimensions.
1)
To equalize pressure and keep the liquid level in the bypass constant with the liquid
level in the vessel.
WARNING: For pressure applications, it will be necessary to use PTFE
tape or other appropriate thread sealing compound, and to tighten the
process connection beyond hand-tight.
Note: There is no limit to the number of times a device can be rotated without damage.
optimum
diameter
80 mm (3”)
align front or
back of
device with
vents
align front or back of
device with stillpipe slots
vent
Stillpipe Installation
slots
B
ypass Installation