User's Manual

Table Of Contents
Page 34 SITRANS LR250 HART) – INSTRUCTION MANUAL 7ML19985JE03
mmmmm
Quick Start: local
1. Enter PROGRAM mode
Point the programmer at the display from a
maximum distance of 300 mm (1 ft).
RIGHT arrow activates PROGRAM
mode and opens menu level 1.
Mode opens the menu level last
displayed in PROGRAM mode within the last
10 minutes, or menu level 1 if power has
been cycled since then.
2. Navigating: key functions in Navigation mode
3. Editing in PROGRAM mode
Selecting a listed option
a) Navigate to the desired parameter.
b) Press RIGHT arrow to open parameter
view.
Notes:
In Navigation mode ARROW keys move to the next menu item in the direction of the
arrow.
For Quick Access to parameters via the handheld programmer, press Home ,
then enter the menu number, for example:
2.7.1 (Volume).
Key Name Menu level Function
UP or DOWN
arrow
menu or parameter
Scroll to previous or next menu or
parameter.
RIGHT arrow
menu
Go to first parameter in the selected
menu, or open next menu.
parameter Open Edit mode.
LEFT arrow
menu or parameter Open parent menu.
Mode menu or parameter Change to MEASUREMENT mode.
Home menu or parameter Open top level menu: menu 1.
display
handheld programmer
Max. 300 mm
(1 ft)
parameter name
parameter
number
current
selection