User's Manual

7ML19985FH01 SITRANS LR 400 – INSTRUCTION MANUAL DRAFT Page 5
mmmmm
Specifications
Mechanical
Nominal sizes DIN DN 80 DN 100 DN 150
ANSI 3" 4" 6"
JIS 80 mm 100 mm 150 mm
Pressure classes
DIN PN16 PN40
ANSI 150 lb 300lb
JIS 10K
Flange
Process Connection Flange DIN 2527, ANSI B16.5, or JIS B2238 equivalent bolt
pattern
Materials of the wetted Stainless steel, material–no. 1.4571 and 1.4581, PTFE
parts –in contact with (or glass/PTFE, Zone 0 and Zone 20 devices)
the process
Enclosure
construction Die-cast aluminum, painted
conduit M20 (cable diameter 6 to 9.5 mm[0.24 to 0.37"])
or ½”-14 NPT
ingress protection Type 4X/NEMA 4X, Type 6/NEMA 6, IP 67
1
Weight
Weight of unit and flange
1.
Use only approved, suitable sized hubs for watertight applications.
Flange Pressure Class Size Weight
DIN 2527 PN 16 DN 80 11.9 kg (26.1 lbs)
DN 100 13.2 kg (28.9 lbs)
DN 150 19.2 kg (42.1 lbs)
PN 40 DN 80 12.9 kg (28.4 lbs)
DN 100 15.5 kg (34.1 lbs)
DN 150 24.1 kg (43.1 lbs)
ANSI B 16.5 150 lb 3" 12.2 kg (26.8 lbs)
4" 14.8 kg (32.5 lbs)
6" 20.1 kg (44.2 lbs)
300 lb 3" 14.3 kg (31.5 lbs)
4" 20.2 kg (44.4 lbs)
6" 31.8 kg (69.9 lbs)
JIS B2238 10K 80 mm 11.9 kg (26.1 lbs)
100 mm 13.2 kg (28.9 lbs)
150 mm 19.2 kg (42.1 lbs)
sitranslrd3.book Page 5 Tuesday, October 9, 2001 10:09 AM