User's Manual
Table Of Contents
- Table of Contents
- SITRANS LR 460
- Specifications
- Installation
- Wiring
- 4-20 mA Start Up
- Local Operation
- LCD menu structure
- HART Communications
- Remote operation via PROFIBUS PA
- PROFIBUS PA Profile Structure
- Appendix A: Parameter Descriptions
- 1. Identification
- 2. Input
- 3. Output
- 5. Maintenance settings
- 6. Condensed Status Setup
- 6.1. Condensed Status Mode
- 6.1.1. Loss of Echo S0 (Status; Diagnosis)
- 6.1.2. Cable Fault S1 (Status; Diagnosis)
- 6.1.3. No Tech Power S2 (Status; Diagnosis)
- 6.1.4. Device Lifetime Maintenance Required Limit S3 (Status; Diagnosis)
- 6.1.5. Device Lifetime Maintenance Demanded Limit S4 (Status; Diagnosis)
- 6.1.8. Sensor Lifetime Maintenance Demanded Limit S7 (Status; Diagnosis)
- 6.1.9. Device Service Maintenance Required Limit S8 (Status; Diagnosis)
- 6.1.10. Device Service Maintenance Demanded Limit S9 (Status; Diagnosis)
- 6.1.11. LTB Scale S10 (Status; Diagnosis)
- 6.1.12. Internal Temp Sensor S11 (Status; Diagnosis)
- 6.1.13. Internal Temp High S12 (Status; Diagnosis)
- 6.1.16. AIFB2 PV Range S15 (Status; Diagnosis)
- 6.1.19. Calibration Schedule Maintenance Demanded Limit S18 (Status; Diagnosis)
- 6.1.30. Memory EEPROM S29 (Status; Diagnosis)
- 6.1.31. Memory EEPROM Flags S30 (Status; Diagnosis)
- 6.1.32. Memory Flash S31 (Status; Diagnosis)
- 6.1.33. Ident Violation S32 (Status; Diagnosis)
- 6.1.34. Internal Temperature Calibration S33 (Status; Diagnosis)
- 6.1. Condensed Status Mode
- Appendix B: Technical Reference
- Appendix C: Troubleshooting
- Appendix D: Maintenance
- Appendix E: Software Revision History
- Glossary
- Index
7ML19985JM01 SITRANS LR 460 (4-20 mA) – INSTRUCTION MANUAL Page II-27
mmmmm
mA: Startup
Programming SITRANS LR 460
The parameters that control the operation of the LR 460 are organized into function
groups, and arranged in a 4-level menu structure that can be accessed either via the
handheld programmer, or via PDM (see
LCD menu structure
on page 37).
The handheld programmer
1
To activate PROGRAM mode, point the handheld programmer at the display (from a
maximum distance of 600 mm [2 ft.]), and press the Mode key .
The handheld programmer has two modes of operation:
1. Navigation Mode
• In this mode, the rightmost digit of the menu number flashes (the Edit Mode
icon is not visible).
• Press Up or Down arrow to change the menu number.
• Press Right or Left arrow once to move to the next/previous menu level.
• Press Right arrow again to switch from Navigation to Edit Mode
2
, or vice versa.
1.
See
Programming via the handheld programmer
on page 33 for more detail.
Note: For Quick Access to parameters via the handheld programmer, press Mode key
to activate PROGRAM mode, followed by Home key , then enter the menu
number (see
LCD menu structure
on page 37 for details).
2.
When there is no further menu sub-level to access.
display
handheld
programmer
max. 600 mm
(2 ft.)
5
9
C
6
0
7 8
1 2 3 4
numeric keys
function
Keys