User's Manual
Table Of Contents
- Table of Contents
- SITRANS LR 460
- Specifications
- Installation
- Wiring
- 4-20 mA Start Up
- Local Operation
- LCD menu structure
- HART Communications
- Remote operation via PROFIBUS PA
- PROFIBUS PA Profile Structure
- Appendix A: Parameter Descriptions
- 1. Identification
- 2. Input
- 3. Output
- 5. Maintenance settings
- 6. Condensed Status Setup
- 6.1. Condensed Status Mode
- 6.1.1. Loss of Echo S0 (Status; Diagnosis)
- 6.1.2. Cable Fault S1 (Status; Diagnosis)
- 6.1.3. No Tech Power S2 (Status; Diagnosis)
- 6.1.4. Device Lifetime Maintenance Required Limit S3 (Status; Diagnosis)
- 6.1.5. Device Lifetime Maintenance Demanded Limit S4 (Status; Diagnosis)
- 6.1.8. Sensor Lifetime Maintenance Demanded Limit S7 (Status; Diagnosis)
- 6.1.9. Device Service Maintenance Required Limit S8 (Status; Diagnosis)
- 6.1.10. Device Service Maintenance Demanded Limit S9 (Status; Diagnosis)
- 6.1.11. LTB Scale S10 (Status; Diagnosis)
- 6.1.12. Internal Temp Sensor S11 (Status; Diagnosis)
- 6.1.13. Internal Temp High S12 (Status; Diagnosis)
- 6.1.16. AIFB2 PV Range S15 (Status; Diagnosis)
- 6.1.19. Calibration Schedule Maintenance Demanded Limit S18 (Status; Diagnosis)
- 6.1.30. Memory EEPROM S29 (Status; Diagnosis)
- 6.1.31. Memory EEPROM Flags S30 (Status; Diagnosis)
- 6.1.32. Memory Flash S31 (Status; Diagnosis)
- 6.1.33. Ident Violation S32 (Status; Diagnosis)
- 6.1.34. Internal Temperature Calibration S33 (Status; Diagnosis)
- 6.1. Condensed Status Mode
- Appendix B: Technical Reference
- Appendix C: Troubleshooting
- Appendix D: Maintenance
- Appendix E: Software Revision History
- Glossary
- Index
7ML19985JM01 SITRANS LR 460 – INSTRUCTION MANUAL Page 39
mmmmm
E: LCD menus
1. AIFB1
2. AIFB2
3. mA Output
4. Relay Config
1. Target Mode
2. Unit
3. Filter Time Constant
4. Channel
5. Batch Information
6. Process Value Scale
7. Output Scale
8. Output Limits
9. Failsafe Mode
A. Interface
1. Failsafe Mode
2. Failsafe Value
Output AIFB1
Failsafe Mode
3. Output
1. Batch ID
2. Batch Unit
3. Batch operation
4. Batch Phase
Batch Information
1. Lower Value
2. Upper Value
Process Value Scale
Output Scale
1. Lower Value
2. Upper Value
Output Limits
1. Lower Limit Alarm
2. Lower Limit Warning
3. Upper Limit Warning
4. Upper Limit Alarm
5. Limit Hysteresis
6. Min. Out
7. Max Out
A. Decimal Point
Interface
1. Target Mode
2. Unit
3. Filter Time Constant
4. Function
5. Batch Information
6. Process Value Scale
7. Output Scale
8. Output Limits
9. Failsafe Mode
A. Interface
1. Failsafe Mode
2. Failsafe Value
AIFB2
Failsafe Mode
1. Batch ID
2. Batch Unit
3. Batch operation
4. Batch Phase
Batch Information
1. Lower Value
2. Upper Value
Output Scale
1. Lower Value
2. Upper Value
Output Limits
1. Lower Limit Alarm
2. Lower Limit Warning
3. Upper Limit Warning
4. Upper Limit Alarm
5. Limit Hysteresis
6. Min. Out
7. Max Out
A. Decimal Point
Interface
Process Value Scale
1. Function
2. Output value
3. Manual value
4. Min limit
5. Max limit
6. FS mode
7. FS value
8. 4 mA Trim
9. 20 mA Trim
mA Output
1. AIFB
2. Function
3. NC/NO
4. State
Relay config