User's Manual

Table Of Contents
7ML19985LY01 SITRANS LR560 (FF) – OPERATING INSTRUCTIONS Page 7
mmmmm
SITRANS LR560 (FF)
Local Display Interface (LDI)
LDI may be ordered installed or added later as an
option
can be mounted in 1 of 4 positions at 90 degree
intervals, for easy viewing after installation
displays level and diagnostic information
including echo profile and trend over time
backlit for easy viewing in dimly lit areas
allows you to copy parameters from one device
to another
provides high speed firmware transfer capabilities for future upgrades
Versions
Two different versions of the LR560 are available:
40 m range, 100 °C maximum process temperature
100 m range, 200 °C maximum process temperature
Applications
cement powder, plastic powder/pellets, grain, flour, coal, and other applications
solids bulk storage vessels
Approvals and Certificates
SITRANS LR560 is available with General Purpose or Hazardous approvals. For details
see
Approvals
on page 10.
Application
Type
LR560
Version
Approval Rating Valid for: Wiring
Non-
hazardous
General
Purpose
CSA
US/C
, FM, CE, C-TICK
N. America,
Europe
See
page 23
Hazardous
Non-Sparking/
Energy Limited
ATEX II 3G Ex nA/nL IIC T4 Gc Europe
See
page 28
Dust Ignition
Proof
ATEX II 1D, 1/2D, 2D
IECEx SIR 09.0149X
Ex ta IIIC T139
o
C Da
Europe and
International
See
page 28
FM/CSA:
Class II, Div. 1, Groups E, F, G
Class III T4
US/Canada
See
page 28
Non-incendive
FM/CSA:
Class I, Div. 2, Groups A, B, C, D T4
US/Canada
See
page 28