User's Manual
Table Of Contents
- Safety Notes
- FCC Conformity
- CE Electromagnetic Compatibility (EMC) Conformity
- Industry Canada
- The Manual
- Technical Support
- SITRANS LR560 Overview
- Specifications
- Installation
- Wiring
- Local Operation
- Operating via AMS Device Manager
- Functions in AMS Device Manager
- Programming via AMS Device Manager
- Adding a new device
- Startup
- Configuring a new device
- Changing Block Modes
- Configure/Setup Parameters
- Transducer Block Parameters
- Level Transducer Block Parameters
- Operation (LTB)
- Simulation (Input)
- Setup (LTB)
- General
- Calibration
- Rate
- Signal Processing (LTB)
- Range
- Echo Select
- Sampling
- Echo Quality
- Filtering
- TVT Setup
- TVT Shaper 1
- TVT Shaper 2
- TVT Shaper 3
- Echo Profile Parameters (view only)
- Maintenance & Diagnostics (LTB)
- Sensor Lifetime
- Service Schedule
- Communication (LTB)
- Communication:
- Configure/Setup (Liquid Crystal Display Block-LCD)
- Configure/Setup (Diagnostic Transducer Block-DIAG)
- Configure/Setup (Resource Block - RESOURCE)
- Device Diagnostics (Level Transducer Block - LTB)
- Device Diagnostics (Level Control Device Block - LCD)
- Device Diagnostics (Diagnostic Transducer Block - DIAG)
- Device Diagnostics (Resource Block - RESOURCE)
- Password Protection
- AMS Menu Structure
- Parameter Reference
- 1. Quick Start
- 2. Setup
- 2.1. Identification
- 2.2. Device
- 2.3. Sensor
- 2.4. Signal Processing
- 2.4.1. Near Range
- 2.4.2. Far Range
- 2.4.3. Minimum Sensor Value
- 2.4.4. Maximum Sensor Value
- 2.4.5. Echo Select
- 2.4.6. Sampling
- 2.4.7. Echo Quality
- 2.4.8. TVT (Auto False Echo Suppression) Setup
- 2.4.9. TVT Shaper
- 2.4.9.1. Shaper 1-9
- 2.4.9.2. Shaper 10-18
- 2.4.9.3. Shaper 19-27
- 2.4.9.4. Shaper 28-36
- 2.4.9.5. Shaper 37-45
- 2.4.9.6. Shaper 46-54
- 2.4.9.7. Shaper 55-63
- 2.4.9.8. Shaper 64-72
- 2.4.9.9. Shaper 73-81
- 2.4.9.10. Shaper 82-90
- 2.4.9.11. Shaper 91-99
- 2.4.9.12. Shaper 100-108
- 2.4.9.13. Shaper 109-117
- 2.4.9.14. Shaper 118-120
- 2.5. AIFB 1
- 2.6. AIFB 2
- 2.7. Measured Values
- 2.8. Filtering
- 3. Diagnostics
- 4. Service
- 5. Communication
- 6. Security
- 7. Language
- Appendix A: Alphabetical Parameter List
- Appendix B: Troubleshooting
- Appendix C: Maintenance
- Appendix D: Technical Reference
- Principles of Operation
- Echo Processing
- Measurement Range
- Measurement Response
- Damping
- Loss of Echo (LOE)
- Temperature derating curves
- Appendix E: Communications
- Appendix F: Firmware Revision History
- Glossary
- Index
- LCD menu structure
Page 44 SITRANS LR560 (FF) – INSTRUCTION MANUAL 7ML19985LY01
mmmmm
AMS Device Manager
Adding a new device
Electronic Device Description (EDD)
Check the product page of our website at: www.siemens.com/LR560, under Support >
Software Downloads, for the latest version of EDD: SITRANS LR560 FF - Foundation
Fieldbus - AMS V9.0.
1) Check that you have the latest version of the EDD for AMS Device Manager that
matches the firmware revision of your device. (See Firmware Revision (2.2.2.) on
page 90 to access it via the local user interface). If necessary download the EDD
from the product page listed above.
2) Save the files to your computer, and extract the zipped file to an easily accessed
location.
3) Launch AMS Device Manager – Add Device Type, browse to the unzipped EDD file
and select it.
4) If desired, enter a new device tag. The device is shipped with a unique tag,
consisting of a manufacturer id and serial number
1)
. It is not necessary to change
the device tag to make the device operational.
To change Device Tag:
a) Launch AMS Device Manager – AMS Device Manager.
b) From Device Connection View, right click on the FF Network icon and select
Rebuild Hierarchy.
c) Right click on the device icon, and choose Rename from the menu.
d) Enter a device tag and press Enter.
Startup
1) Launch AMS Device Manager
a) Launch AMS Device Manager – AMS Device Manager.
b) From Device Connection View, right click on the FF Network icon and select
Rebuild Hierarchy.
c) If you wish to rename the device, right-click on the device icon and select
Rename from the menu, enter a new device tag, and click Enter.
d) Double-click the device icon. The Configure/Setup menu opens at the device
Identification dialog window. At initial startup, the Block Status is Out of
Service.
Note: SITRANS LR560 requires the EDD for AMS Device Manager version 9.0.
1)
The device tag is read-only via local operation.
Note: The Device Tag described above is distinct from the Tag that describes each block
type (located in the
Identification
folder of each block).