RUGGEDCOM SAS-GW
User Guide
Chapter 4
Configuring RUGGEDCOM SAS-GW
Adding a Base Station 49
Parameter Description
SAS Control Synopsis:  { Enabled, Disabled, Off the Grid }
Default:  Enabled
Defines how RUGGEDCOM SAS-GW will handle the base station. Options include:
Enabled – The base station will be reported to the SAS.
Disabled – The base station will not be reported to the SAS. However, RUGGEDCOM
SAS-GW will still query the device for its status.
Off the Grid – The base station will not be registered or queried. Any subscriber
units connected to the base station will also be unknown to RUGGEDCOM SAS-GW.
3. Select the SNMP tab. The SNMP tab appears.
6
5
1
4
2
3
Figure32:SNMP Tab
1.SNMP Version List 2.V2c Read Community Box 3.V2c Write Community Box 4.Apply Button 5.Fetch Data Button
6.Fetch Installation Parameters Button
4. Configure the following parameters:
Parameter Description
SNMP Version Synopsis:  { SNMPv2c, SNMPv3-NA }
Default:  SNMPv2c
The version of SNMP used by the base station.
V2c Read Community Synopsis:  A string
Default:  public
The name of the SNMP read community.