User's Guide

Table Of Contents
RUGGEDCOM SAS-GW
User Guide
Chapter 4
Configuring RUGGEDCOM SAS-GW
Updating CPI Information 65
8
6
7
2
1
3
4
5
Figure46:CPI Tab
1.CPI List 2.CPI ID Box 3.CPI Name Box 4.Install Certification Time Box 5.CPI Certificate Private Key Box 6.Apply Button
7.Delete Button 8.Deregister from SAS Button
3. Under CPI, select one of the following options:
Disabled – The information is not relayed by a CPI
Enabled – The information is relayed by a CPI
If Disabled is selected, skip the next step.
4. Configure the following remaining parameters:
Parameter Description
CPI ID Synopsis:  A string of up to 256 characters
The ID of the CPI providing the information to the SAS.
CPI Name Synopsis:  A string of up to 256 characters
The name of the CPI providing the information to the SAS.
Install Certification Time The UTC date and time when the CPI installed the device. The value must be defined in
the form of YYYY-MM-DDThh:mm:ssZ. For example: 2018-01-01T00:00:00Z
CPI Certificate Privatization Key The path on the device to the certificate private key file.
5. Click Apply.