User's Guide
Table Of Contents
- RUGGEDCOM SAS-GW
- Table of Contents
- Preface
- 1. Introduction
- 2. Installation and Deployment
- 3. Using RUGGEDCOM SAS-GW
- 4. Configuring RUGGEDCOM SAS-GW
- 4.1. Configuring the Local Time Zone
- 4.2. Configuring the SNMP Read/Write Communities
- 4.3. Managing User Accounts
- 4.4. Managing Base Stations
- 4.4.1. Adding a Base Station
- 4.4.2. Updating a Base Station's Configuration
- 4.4.3. Updating a Base Station's Location
- 4.4.4. Updating a Base Station's Antenna Characteristics
- 4.4.5. Updating SNMP Settings
- 4.4.6. Updating CPI Information
- 4.4.7. Removing a Base Station
- 4.4.8. Viewing Available Base Stations
- 4.4.9. Viewing the Measurements Report
- 4.4.10. Viewing the SAS Registration Information
- 4.5. Managing Subscriber Units
- 5. Monitoring RUGGEDCOM SAS-GW
RUGGEDCOM SAS-GW
User Guide
Chapter 4
Configuring RUGGEDCOM SAS-GW
Adding a Subscriber Unit 79
Parameter Description
• Directional – Directional antenna
Beam Width Synopsis: A number between 0 and 360
The width of the antenna's beam, measured in degrees (°), on the horizontal-plane.
A value of 360 means the antenna has an omni-directional radiation pattern in the
horizontal plane.
c. [Optional] Configure the following additional parameter:
Parameter Description
Model Synopsis: A string between 1 and 128 characters
The platform name or part number of the antenna (e.g. WIN5137).
d. Click Apply.
4. Define the frequency spectrum.
a. Click Antenna. The Antenna tab appears.
1
3
2
Figure59:Antenna Tab
1.Frequency Start Box 2.Frequency Stop Box 3.Apply Button
b. Configure the following parameters:
Parameter Description
Frequency Start Synopsis: A number between 3550000 and 37700000
The low value of the frequency bandwidth, measured in kilohertz (KHz), in which the
subscriber unit operates.
Frequency Stop Synopsis: A number between 3550000 and 37700000
The high value of the frequency bandwidth, measured in kilohertz (KHz), in which
the subscriber unit operates.
c. Click Apply.