User's Guide

Table Of Contents
RUGGEDCOM SAS-GW
User Guide
Chapter 4
Configuring RUGGEDCOM SAS-GW
Updating a Subscriber Unit's Configuration 81
1
7
2
3
4
5
6
8
Figure61:Update SU Screen
1.CPE Name Box 2.IP Address Box 3.MAC Address Box 4.Serial Number Box 5.SS Max Tx Power Box 6.SS Max EIRP Box
7.SAS Control List 8.Report Measurements to SAS List 9.CBSD Device Category List 10.CBSD Group List 11.Apply Button
12.Delete Button
2. On the General tab, update the following parameters as needed:
Parameter Description
SU Name Synopsis:  A string
A unique name for the subscriber station.
IP Address Synopsis:  An IPv4 address
The subscriber station's IP address.
MAC Address Synopsis:  A string
The subscriber station's MAC address.
Serial Number Synopsis:  A string
The serial number assigned to the subscriber station by the vendor.
SU Max Tx Power Synopsis:  A number between 17 and 27
The maximum transmission (Tx) power in dBm/10 MHz.
SU Max EIRP Synopsis:  A number
The maximum EIRP, measured in decibels-per-minute/megahertz (dBm/MHz) permitted
by the grant.
SAS Control Synopsis:  { Enabled, Disabled, Off the Grid }
Default:  Enabled