Configuring RUGGEDCOM SAS-GW
Removing a Subscriber Unit 89
1
3
2
4
Figure69:Spectrum Tab
1.Frequency Start Box 2.Frequency Stop Box 3.Apply Button 4.Delete Button
3. Update the following parameters as needed:
Parameter Description
Frequency Start Synopsis:  A number between 3550000 and 37700000
The low value of the frequency bandwidth, measured in kilohertz (KHz), in which the
subscriber unit operates.
Frequency Stop Synopsis:  A number between 3550000 and 37700000
The high value of the frequency bandwidth, measured in kilohertz (KHz), in which the
subscriber unit operates.
4. Click Apply.
Section4.5.6
Removing a Subscriber Unit
To remove a subscriber unit from RUGGEDCOM SAS-GW, do the following:
1. Left-click the subscriber unit on the map and then click Edit. The Update SS screen appears.