User's Manual

WiN7000 cBST cBST WEB Manager | 124
Possible values: [0..1]. Default value is 0 (false).
initSleepWindow
Initial Sleep window, in frame quantity.
Integer in range [0..255].
Required parameter.
listenWindow
Listening window, in frame quantity.
Integer in range [0..255].
Required parameter.
finalSleepWindowBase
Final Sleep window base, in frame quantity.
Integer in range [0..1023].
Required parameter.
finalSleepWindowExp
Final Sleep window exponent.
Integer in range [0..7].
Required parameter.
cidQty
CID quantity.
Integer in range [0..7]. Default value is 0, for all the CIDs of the MS.
cidList
CID list.
String.
setQosDl
Other tab.
Configures downlink QoS.
Parameters
above-minrate-mode
Mode when above the minimum rate:
[roundrobin | strict | weightedFair]
where:
roundrobin All DL CIDs are served by the BS one by one in a sequential manner.