User's Manual

WiN7000 cBST Installation Procedures | 31
4.1 Safety Hazards
Warning:
Installing WiN7000 can pose a serious hazard. Be sure to take precautions to avoid the
following:
Exposure to high voltage lines during installation
Falling when working at heights or with ladders
Injuries from dropping tools
Contact with AC wiring (power system connection)
Antenna Grounding Requirements: The antenna installation must be as per Article 810 of the
NEC. Of particular note is the requirement that the grounding conductor not be less than 10
AWG (Cu). The scheme should be either in accordance with UL 96 and 96A. Lightning
Protection Components and Installation Requirements for Lightning Protection Systems, or
tested in accordance with UL 50 and UL 497.
4.2 Installation Tools
1. Screwdriver
2. Wrench
3. Driller
4. Hammer
4.3 Installing the WiN7000
Important
The equipment should be installed in accordance with the National Electrical Code (NEC),
ANSI/NFPA 70, the Canadian Electrical Code (CEC), Part 1, CSA C22.1; and when
applicable, the National Electrical Safety Code IEEE C2. And unless marked or otherwise
identified, the Standard for the Protection of Electronic Computer/Data Processing
Equipment, ANSI/NFPA 75.
The installation involves the WiN7000 device and the mounting bracket. The mounting
bracket should be installed first, followed by WiN7000, which should be inserted into it, as
explained below.