User's Manual

WiN7000 cBST Management | 53
6.1 General
The WiN7000 cBST can be monitored and controlled with a standalone PC or through a
management system (WiNMS) using the backhaul interface. The monitoring and control
capabilities are similar in both cases but the interface may be different. This chapter describes
the monitoring and control capabilities.
The local PC can connect to the internal web server using HTTP.
The management of the WiN7000 cBST device uses SNMP. The WiN7000 cBST has a standard
MIB II and propriety MIB.
There are no local displays on the BS. All the indications will have to be monitored via the
management system (WiNMS).
6.2 SW Download/Upgrade
The software can be loaded into the WiN7000 cBST using one of the following methods:
Using a local PC (connected to the nearby switch) that has an FTP server running on it;
Through remote SNMP (over the backhaul interface), using the WiNMS.
The WiN7000 cBST supports a complete rollback option to be used in case the upgrade fails.
1. In the HostIpAddress field, enter the FTP server IP address.
2. In the FileDirectory field, enter the directory in which the new SW files are located.
This directory should contain a <filename>.pkg file.
3. In the PackageFileName field, enter in the file name of the .pkg file.
4. Enter in the username and password of the FTP server in the appropriate fields.
5. Click the "call" button.
6. Wait for the upgrade process to complete.
6.3 Web-Based Management
The monitored and controlled parameters are available through a web interface.
Please refer to the Equipment Configuration and Monitoring chapter for a description of the
basic configuration and monitoring screens.
For details see cBST WEB Manager chapter.