3.3 Required Tools and Materials
In order to install the Pico BST, a standard professional toolbox is required.
3.4 Installing the Pico BST
Note: Should be installed at highest possible point!
Important!
The equipment should be installed in compliance with the National Electrical Code (NEC),
ANSI/NFPA 70, the Canadian Electrical Code (CEC), Part 1, CSA C22.1; and when applicable, the
National Electrical Safety Code IEEE C2. Unless marked or otherwise identified, the Standard for
the Protection of Electronic Computer/Data Processing Equipment, ANSI/NFPA 75.
There are two types of installations for the Pico BST:
Wall mount - The Pico BST can be attached to any wall that can support the load of the
unit.
Pole mount - The unit can be attached to any pipe or pole with diameter 1.75” to 10".
3.4.1 Overview
The Pico BST installation procedure consists of the following steps:
1. Covering the Console port (only used for maintenance purposes by authorized personnel) –
see
3.4.2.
2. Assembling the PoE connector – see
3.4.3.
3. Assembling the Pico BST mounting bracket – see
3.4.4.
4. Mounting the Pico BST (wall/pole mount) – See
3.4.5.
5. Antenna connections and grounding – see
3.4.6.
6. Connecting the Win7200 Data Adapter – see
3.4.7.
7. See chapter
4 for the initial Setup procedure.