User's Manual

Table Of Contents
RUGGEDCOM WIN7000
Installation Guide
Chapter 3
Installation Procedures
Power and Cable Connections 15
Section 3.4.6
Power and Cable Connections
There are three power connection options for the WIN7000, which are described in the following sections. The
power connection options are as follows:
PEC (Copper) Type Base Station
SFA (Optical) Type Base Station
SFD Type Base Station
The WIN7000 can be equipped with copper or fiber Ethernet connections. These copper and fiber port options
are described in Section 3.4.6.1, “PEC (Copper) Type Base Station” and Section 3.4.6.2, “SFA (Optical) Type
Base Station”.
Use the following tools to fasten or loosen the connectors:
Description Manufacturer Tool Number Type Torque Connector Name
Type-N 1 Nm Variant
Wrench, 20 mm
Tessco 13055 Hexagon 1.35 N·m (11.9 lbf-in) ANT1/ANT2
Modular Plugs
Connector Removal
Tool, BNC/TNC, 12"
Ideal 35-042 Round 0.56 N·m (4.9 lbf-in) GPS
Curved Jaw Locking
Plier
Irvin 502L3 Curved 4 N·m (35.4 lbf-in) DC/ETH
Section 3.4.6.1
PEC (Copper) Type Base Station
The power system is supplied by Siemens (WINPS).
To connect the power system and cables, do the following:
Procedure: Connecting the Power System and Cables
1. Connect the supplied combo (DC + Ethernet cable) to the power system (WINPS) port labeled DC + ETH.
2. Connect the other end to port 6 on the WIN7000 unit as shown in Figure 9.
3. Connect the Ethernet input to the 10/100 Base-T connector on the power system.
The following figure shows the physical connection between the WIN7000, the power system, and the AC power
source.