User's Manual
Table Of Contents
- RUGGEDCOM WIN7000
- Table of Contents
- FCC Statement and Cautions
- 1. Introduction
- 1.1. About this Guide
- 1.2. Capabilities and Features
- 1.3. Safety Information
- 1.3.1. General
- 1.3.2. Power Supply Requirements
- 1.3.3. Equipment Installation
- 1.3.4. Radio Frequency (RF) Exposure
- 1.3.5. Lightning Protection
- 1.3.6. Power Cord Protection
- 1.3.7. Servicing
- 1.3.8. Antenna Grounding Requirements
- 1.3.9. Outdoor Grounding System
- 1.3.10. User Ports and Power Supply
- 1.3.11. Safety Hazards
- 1.4. WIN7000 Physical Specifications
- 2. Site and Installation Requirements
- 3. Installation Procedures
- 3.1. Pre-Installation Safety Instructions
- 3.2. Package Components and Unpacking
- 3.3. Installation Tools
- 3.4. Installing the Base Station
- 3.5. Weatherproofing
- 3.6. Hazardous Location Information
- 3.7. Hazardous Location Installation
- 4. Setup
- 5. Troubleshooting
- Appendix A. Connector and Cable Pinouts
- Appendix B. WIN7000 Specifications
- Appendix C. List of Acronyms
- Appendix D. Warranty
Chapter 3
Installation Procedures
RUGGEDCOM WIN7000
Installation Guide
30 Weatherproofing
Figure 27: C+D Band Cavity Filter Antenna Connections
Section 3.5
Weatherproofing
It is extremely important to weatherproof all outdoor cable connections. Weatherproofing the connections at the
outdoor unit and antennas prevents corrosion, prevents water from interfering with the connection, and helps to
keep the connection tight. Because cables also carry DC current, the need for proper weatherproofing cannot be
overstated.
We recommend the use of sealing tapes designed for outdoor use:
• 3M™ Scotch® Super 88 Electrical Tape
• Heavy-duty weather-, abrasion-, and UV-resistant rubber splicing tape or self-amalgamating tape
Rubber mastic putty or duct sealing putty must also be used to complete the weatherproofing where needed.
We do not recommend silicon seal or glue. These materials are difficult to apply accurately and are difficult to