User's Manual

Table Of Contents
Chapter 4
Setup
RUGGEDCOM WIN7000
Installation Guide
38 Connecting to the WIN7000 Web Interface
Figure 35: Microsoft Windows Local Area Connection Properties dialog box
5. In the Items list, select Internet Protocol (TCP/IP) and click the Properties button. The Internet Protocol
(TCP/IP) Properties dialog appears.
6. Assign your computer the IP address 192.168.100.99 and the subnet 255.255.255.0.
Figure 36: Microsoft Windows Internet Protocol (TCP/IP) Properties dialog box
7. On the Internet Protocol (TCP/IP) Properties dialog, click OK. On the Local Area Connection Properties
dialog, click Close.
8. Launch your web browser and type https://192.168.100.100 in the address field.